Symmetry enclosed lift vertical platform lift
Vertical Platform lifts

Symmetry Enclosure

Vertical Platform liftsSymmetry Enclosure

Enclosed Lift

The Enclosed Lift is A18.1 code-compliant and designed for ease of installation. It can be used as a residential lift or in a commercial application.

When used in private residences, the Enclosure vertical platform lift requires slightly more space than an Unenclosed lift. They travel heights up to 168″. You may see an Enclosed lift in commercial settings, including parking structures, airport terminal lifts, and providing access to stadium seating.

Proudly made in the U.S.A.

High-quality, US-made vertical platform lifts. Cibes Symmetry: Your trusted lift solutions provider with national reach and local service

No shaft required

All-inclusive lift solution. The enclosure is the shaft and it comes with it.

Design options

Experience enhanced customization options with Symmetry Enclosure, tailoring it to perfectly suit your unique requirements.

Enclosure Lift Plexi-glass (ELP)

The Enclosed plexi-glass vertical platform lifts are used in the same way as the enclosed lift, with plexi-glass infill enclosure wall panels. It requires slightly more space than an unenclosed lift and travel heights up to 168″.

  • Suitable for indoor and outdoor use in Acme Screw and Hydraulic drive systems. 

Can provide weather protection

Option to do an ELP outdoors with a roof to account for weather.

Transparent walls

Take in your surroundings with clear panels, making it less visually intrusive.

Commercial applications

If the manufacturer is to provide the enclosure, it is an Enclosed Lift.

An Enclosed platform lift is designed to meet the requirements of ASME A18.1, so all platform sizes and running clearances have been taken into consideration, and the lift constructed accordingly.

Ivory enclosure lift outdoors in commercial setting with roof

Optimized solutions for commercial spaces

The entrances to the lift are incorporated into the lift’s enclosure, which requires you to provide only the required structural support and entry and exit points.

While an Enclosed wheelchair lift may have a higher upfront cost than a Shaftway Lift, it’s essential to account for the cost of construction of the shaft for a fair comparison. 

Commercial elevators

Enclosed platform lift installation

Commercial setting

Meet Joshua, the General Manager of Alexander’s Steak House in Peoria, IL, as he shares his firsthand experience with the installation of a Symmetry Enclosed VPL.

Discover how this exceptional lift, installed by an authorized Cibes Symmetry dealer, has transformed their accessibility.

Enclosure options

There are two enclosure options to choose from:

  • Metal Infill enclosure wall panels for EL 
  • Acrylic or Laminated Safety Glass infill enclosure wall panels for ELP 
Symmetry VPL customizations

Technical highlights

The Symmetry Enclosure VPL has a rated load of 750 lbs. The lift moves as a speed of 10-20 fpm (depending on drive option).

Constant pressure

Unlike a residential elevator, constant pressure on the call button is required when calling the lift to the appropriate landing and when a passenger sends the lift to the desired level.

white unenclosed lift porch lift outdoor

Integrated doors and locks

Landing interlocks keep doors closed/locked when the platform is at another landing, ensuring safety at all times.

Drive options

There are a variety of drive options to choose from with the Symmetry Enclosed platform lift:

  • Acme Screw Drive: 10 fpm, 1 HP, 115 VAC
  • Accelerated Acme Screw Drive: 20 fpm, 1 HP, 115 VAC
  • Chain Hydraulic Drive: 17-20 fpm, 3 HP/24 VDC, 115 VAC

Roof and ventilation system for outdoor applications

*Per code, the ventilation system is required when the VPL-ELP has clear plexiglass and is exposed to direct sunlight.

Sloped roof

Symmetry's VPLs are available with a sloped roof. The sloped roof option for VPL-EL and VPL-ELP applications protects the lift and the passenger from weather. Symmetry's roof option is available as single sloped or double sloped and is painted to match the finish of your lift.

enclosed lift with power venilation system

Power ventilation system

This is an optional feature for VPL-EL and VPL-ELP units manufactured with a roof, located at the top landing of the lift, allowing air exchange. Thermostat controlled to activate when the temperature reaches 90-degrees, the power ventilation system will assist in improving passenger comfort by circulating air once per minute when the lift is active.

stainless steel and clear laminated safety glass

Office application

The benefit of the Enclosed wheelchair lift is that the manufacturer has designed and built the lift to meet specific code requirements, removing the need for site adjustments to bring the lift into compliance

Safety features

  • Landing interlocks
  • Grab rails 
  • Non-skid platform surface 
  • Alarm and emergency stop switch
  • Upper final limit switch (optional on Hydraulic Drive)
  • Safety lift nut for Acme Screw Drive
  • Broken chain safeties for Hydraulic Drive

ADA compliant

The Enclosed wheelchair lift is designed and manufactured to comply with ASME A18.1, ICC A117.1, and NFPA 70.

Code of compliance
  • Do vertical platform lifts need a lift pit?

    Vertical platform lifts can be installed on grade or within a pit. If installed in a pit, there will be a smooth transition from the finished floor to the lift platform, otherwise a ramp will need to be provided to overcome the transition. A pit will need to be provided with proper drainage to prevent the collection of water.

  • What is the difference between a wheelchair lift and a vertical platform lift?

    A vertical platform lift is a specific type of wheelchair lift. Vertical platform lifts have a platform which travels straight up and down, as opposed to an incline such as a staircase. The vertical platform lifts from Cibes Symmetry are available for residential or commercial use. Commercial vertical platform lifts are approved in the ADA Accessibility Guidelines as a means to provide unassisted entry and exit from buildings, service or recreational facilities.

  • How can you make a building accessible for every visitor?

    Designing an accessible building has many layers. An elevation change of greater than 1/2 inch is considered an architectural barrier. To overcome an elevation change, a ramp, lift, or elevator should be used. Contact a Cibes Symmetry representative to find the best solution for your site.

Find more answers

Specifications and model details

Technical information

  • Installation:Indoor/Outdoor
  • Rated load:750 lbs
  • Power supply:115 VAC/25A/1 PH, 230 VAC/15A/1 PH (not available for Hydraulic)
  • Speed:10 FPM (20 FPM for Accelerated Acme and Hydraulic)
  • Min headroom:80"
  • Lift pit:3" pit or 0" with Access Ramp
  • Drive system:Standard Acme Screw, Accelerated Acme Screw, or Hydraulic
  • Max travel:168"
  • Max number of stops:4
  • Lift controls:Constant Pressure (Hold to Run)
  • Motor Power:1 1/2 HP (3 HP for Hydraulic)
  • Machine room:Self Contained
  • Door configuration:Same side, Straight Through, 90 Degree, 3 Opening
  • Directives and standards:ASME A18.1

Complete specifications and lift sizes

Check out the full Complete specifications and model details of Symmetry Enclosure.

Read more